WEBVTT

1
00:00:00.000 --> 00:00:01.960
Let us understand high availability.

2
00:00:02.840 --> 00:00:05.720
A school keeps two water
pumps so one can help when the

3
00:00:05.720 --> 00:00:09.920
other stops. If both use the
same broken power line, two

4
00:00:09.920 --> 00:00:13.660
pumps do not solve the problem.
Availability depends on the

5
00:00:13.660 --> 00:00:16.700
whole chain and on how quickly
people notice and recover,

6
00:00:16.700 --> 00:00:20.680
not just the number of pumps.
High availability means

7
00:00:20.680 --> 00:00:24.280
meeting an agreed target for
successful service over time.

8
00:00:24.880 --> 00:00:28.480
Redundant components and
recovery reduce downtime, but a

9
00:00:28.480 --> 00:00:31.540
system can never promise
that nothing will ever fail.

10
00:00:32.440 --> 00:00:36.420
Follow the normal path. For
this example, success means a

11
00:00:36.420 --> 00:00:39.260
correct booking response
within its latency objective.

12
00:00:39.960 --> 00:00:43.320
A homepage response alone
does not measure the same user

13
00:00:43.320 --> 00:00:47.540
outcome. Applications run
in separate zones behind a

14
00:00:47.540 --> 00:00:51.500
resilient entry point. The
goal is to avoid losing every

15
00:00:51.500 --> 00:00:54.160
application copy to
the same local failure.

16
00:00:54.160 --> 00:00:58.380
SeatSpot must keep ticket
browsing and booking usable when a

17
00:00:58.380 --> 00:01:02.420
machine or zone fails. Different
features can have different

18
00:01:02.420 --> 00:01:06.340
objectives: cached event
descriptions may remain available

19
00:01:06.340 --> 00:01:09.820
even if booking is temporarily
paused to protect correct

20
00:01:09.820 --> 00:01:13.200
seat allocation. Now change one condition.

21
00:01:14.140 --> 00:01:17.660
Zone A becomes unavailable.
Detection and rerouting consume

22
00:01:17.660 --> 00:01:20.460
time, and requests already
in flight may fail.

23
00:01:20.460 --> 00:01:23.900
The objective allows an
explicitly measured error budget.

24
00:01:24.540 --> 00:01:27.980
A common misunderstanding is
this: Two replicas guarantee

25
00:01:27.980 --> 00:01:32.500
availability. Shared power,
data, credentials or control

26
00:01:32.500 --> 00:01:35.820
planes can fail both
replicas. Think about this.

27
00:01:36.220 --> 00:01:39.560
Two apps run on different
machines but use one unprotected

28
00:01:39.560 --> 00:01:42.720
database. Is the complete
booking path redundant?

29
00:01:43.260 --> 00:01:45.120
Pause the video and make your prediction.

30
00:01:45.880 --> 00:01:49.200
No. A database failure
can still stop both apps.

31
00:01:49.200 --> 00:01:53.180
Follow the entire user
operation, not only the web tier.

32
00:01:54.020 --> 00:01:56.100
Let us reason with a concrete example.

33
00:01:56.680 --> 00:02:01.580
An agreed objective is 99.9%
time availability over an

34
00:02:01.580 --> 00:02:08.840
illustrative 30-day month. 30
× 24 × 60 = 43,200 minutes.

35
00:02:09.560 --> 00:02:14.400
A 0.1% unavailability
budget is 43.2 minutes.

36
00:02:14.400 --> 00:02:18.100
Request-based indicators
use failed eligible requests

37
00:02:18.100 --> 00:02:20.760
instead, so do not mix
the two measurements.

38
00:02:21.560 --> 00:02:24.840
Choose the objective from
business needs and recovery cost.

39
00:02:25.640 --> 00:02:28.340
Measure actual booking success
separately from whether the

40
00:02:28.340 --> 00:02:32.780
homepage responds. These figures
are teaching examples, not

41
00:02:32.780 --> 00:02:37.060
production guarantees. Turn the
idea into a design decision.

42
00:02:37.800 --> 00:02:41.260
Zone B receives new work. It
must have enough capacity,

43
00:02:42.080 --> 00:02:45.280
network access and working
credentials to serve the actual

44
00:02:45.280 --> 00:02:49.720
user operation. Both application
copies need a suitable data

45
00:02:49.720 --> 00:02:53.460
service. A single unprotected
database can still interrupt

46
00:02:53.460 --> 00:02:56.680
bookings even when both
application zones are healthy.

47
00:02:57.300 --> 00:03:00.220
When you try the practice
task, look for this result.

48
00:03:00.820 --> 00:03:04.880
The illustrative time
budget is 43.2 minutes; a

49
00:03:04.880 --> 00:03:07.520
request-based SLI uses different units.

50
00:03:08.500 --> 00:03:11.720
Check your understanding.
Run a controlled failure and

51
00:03:11.720 --> 00:03:14.020
measure booking success and recovery time.

52
00:03:14.020 --> 00:03:18.180
Availability is demonstrated
by user outcomes, not by

53
00:03:18.180 --> 00:03:21.380
counting boxes in a diagram.
Here is a challenge.

54
00:03:21.920 --> 00:03:24.440
Two application replicas run in one zone.

55
00:03:25.060 --> 00:03:28.620
A second zone is added. List
three things to verify before

56
00:03:28.620 --> 00:03:30.500
calling the service highly available.

57
00:03:31.060 --> 00:03:35.031
Pause before the answer. Check
traffic failover/detection,

58
00:03:35.031 --> 00:03:38.440
data-layer availability and
consistency, and survivor

59
00:03:38.440 --> 00:03:43.280
capacity. Also test shared
authentication, DNS and

60
00:03:43.280 --> 00:03:46.500
configuration dependencies
using the agreed user-visible

61
00:03:46.500 --> 00:03:50.720
indicator. For an interview,
define the SLI, time window,

62
00:03:51.100 --> 00:03:54.240
failover and survivor capacity.
Say what you would measure,

63
00:03:54.620 --> 00:03:56.180
not only which tool you would buy.